Kartal Municipality Service Building Rehabilitation Project

Slide Slide
Project Description INLET
Construction Area 21.795 m2
Servicing to 1200 people/day
Energy Rating From C to B
Structure Heat Loss & Heating Load From 43,38 to 37,93 W/m2
Structure Heat Gain & Cooling Load From 50 to 31,11 W/m2
Water Consumption From 30 to 6,9 m3/day (network) & 4,0 m3/day (grey water)
Electric Consumption From 10,1 to 2,93 W/m2

Process Units:

Paper Consumption with Municipality Automation System: From 4.000.000 to 1.500.000 A4 paper/year
Type Of Contract Building and Engineering Works Designed by the Employer